Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Braz. dent. j ; 33(3): 38-46, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384033

ABSTRACT

Abstract This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.


Resumo Este estudo avaliou os instrumentos Reciproc R25 e Pro-R 25 sem uso, após um primeiro e um segundo uso em retratamento endodôntico com perfilômetro 3D por interferometria de luz sem contato, microscópio eletrônico de varredura (MEV) e testes de fadiga cíclica. Vinte dentes unirradiculares foram instrumentados com Reciproc R25 e obturados com guta-percha e cimento endodôntico. Um perfilômetro 3D com uma objetiva 20x usando o software Mx ™ foi usado para avaliar as superfícies da lâmina de corte do Reciproc e Pro-R (n = 5 por grupo) na condição sem uso, após o primeiro e após um segundo uso em procedimentos de retratamento. Após retratamento, o MEV foi usado para avaliar as características topográficas dos instrumentos utilizados. Testes de fadiga cíclica foram realizados para comparar instrumentos novos com instrumentos usados. O teste One-way ANOVA seguido pelo teste de Tukey foi usado para comparar os instrumentos testados nos diferentes estágios. Para comparar os diferentes instrumentos e para avaliação de fadiga cílcica, foi utilizado o Student t-test. Não foram observadas diferenças estatisticamente significantes nas superfícies das lâminas de corte dos instrumentos Reciproc e Pro-R antes e após um e dois usos (p> 0,05). O Reciproc na condição sem uso apresentou maior Sa e Sq quando comparado ao Pro-R (p <0,05). Não foram observadas diferenças entre Reciproc e Pro-R após um e dois usos (p> 0,05). O Reciproc sem uso apresentou maior tempo de fratura do que os instrumentos Pro-R (p<0,05), e apenas o Pro-R apresentou diferenças entre instrumentos novos e usados (p<0,05). Os procedimentos de retratamento com Reciproc e Pro-R não alteraram a topografia da superfície dos instrumentos. Reciproc apresentou maior resistência à fadiga cíclica em comparação com o Pro-R.

2.
Pesqui. bras. odontopediatria clín. integr ; 17(1): e2918, 13/01/2017. tab, graf
Article in English | LILACS, BBO | ID: biblio-914287

ABSTRACT

Objective: To compare the bond strength of three-step and self-etch adhesive systems with and without prior acid etching on bonding of fiberglass posts in root canals. Material and Methods: Experiments were conducted on roots of five upper molars without curvature and sectioned in a cervical-apical direction. With the aid of a highspeed turbine and diamond tips, cylindrical cavities 7 mm in depth and 1.4 mm in diameter were made in the dentine. The roots of the same tooth were used, where the retainers were cemented, thus generating three groups: Group A: Adper Scotchbond Multipurpose Plus (SBMP) + Rely X ARC; Group B: Single Bond Universal (SBU-1) + Rely X ARC, with acid etching prior to adhesive insertion; Group C: Single Bond Universal (SBU-2) + Rely X ARC. The samples were stored in a bacteriological incubator at 37ºC with 100% humidity for 48h and were subsequently cross-sectioned to obtain 3 dentine discs 1mm in thickness. Forty-five specimens were subjected to the push-out test. Results: Through the analysis of variance and Tukey's test, it was found that SBMP showed, with statistical significance (p<0.05), highest bond strength when compared with the SBU-1 and SBU-2 systems. The observed difference in the discs was located in the cervical portion. Conclusion: The three-step adhesive system had higher bond strength with the substrate than the self-etching adhesive only in the disc in the cervical portion; further, statistically, the prior application of phosphoric acid in SBU-1 did not affect its bond strength significantly.


Subject(s)
Acid Etching, Dental/methods , Dental Cements , Glass Ionomer Cements/chemistry , Tensile Strength , Analysis of Variance , Brazil , Dental Pins
3.
Braz. oral res. (Online) ; 31: e74, 2017. tab, graf
Article in English | LILACS | ID: biblio-952085

ABSTRACT

Abstract The aim of this study was to undertake a qualitative and quantitative assessment of nanoscale alterations and wear on the surfaces of nickel-titanium (NiTi) endodontic instruments, before and after use, through a high-resolution, noncontact, three-dimensional optical profiler, and to verify the accuracy of the evaluation method. Cutting blade surfaces of two different brands of NiTi endodontic instruments, Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were examined and compared before and after two uses in simulated root canals made in clear resin blocks. The analyses were performed on three-dimensional images which were obtained from surface areas measuring 211 × 211 µm, located 3 mm from their tips. The quantitative evaluation of the samples was conducted before and after the first and second usage, by the recordings of three amplitude parameters. The data were subjected to statistical analysis at a 5% level of significance. The results revealed statistically significant increases in the surface wear of both instruments groups after the second use. The presence of irregularities was found on the surface topography of all the instruments, before and after use. Regardless of the evaluation stage, most of the defects were observed in the WaveOne instruments. The three-dimensional technique was suitable and effective for the accurate investigation of the same surfaces of the instruments in different periods of time.


Subject(s)
Humans , Titanium/chemistry , Root Canal Preparation/instrumentation , Endodontics/instrumentation , Nickel/chemistry , Reference Values , Surface Properties , Time Factors , Materials Testing , Reproducibility of Results , Imaging, Three-Dimensional/methods , Equipment Design , Interferometry/methods
4.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, graf
Article in English | LILACS | ID: lil-777181

ABSTRACT

The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05). The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05). The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments’ geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.


Subject(s)
Dental Instruments , Root Canal Preparation/instrumentation , Dental Alloys , Dental Stress Analysis , Equipment Design , Materials Testing , Microscopy, Electron, Scanning , Stress, Mechanical
5.
Full dent. sci ; 6(21): 124-129, dez. 2014. tab
Article in Portuguese | LILACS, BBO | ID: lil-750192

ABSTRACT

O presente trabalho teve como objetivo levantar evidˆncias relacionadas …s doen‡as profissionais e/ou ocupacionais que os cirurgiães-dentistas estÆo vulner veis. Elaborou-se mediante a aplica‡Æo de m‚todos expl¡citos e sistematizados de busca, aprecia‡Æo cr¡tica e s¡ntese da informa‡Æo selecionada, uma revisÆo da literatura sobre o tema. Os trabalhos foram selecionados das bases de dados eletr“nicas (PubMed, Bireme, Nature, Scielo e Cochrane), sendo consultados no per¡odo de 1990 a 2013 sobre as seguintes tem ticas: “doen‡as ocupacionais na Odontologia”, “risco ocupacional odontol¢gico”, “Odontologia do trabalho”, “occupational disease Dentistry”, “occupational hazards”, “dentist”, “cirurgiÆo-dentista”, nos idiomas portuguˆs e inglˆs. Selecionaram-se 21 artigos de um total de 40 potencialmente relevantes, identificados nas pesquisas de base de dados, que reportaram sobre as diversas doen‡as ocupacionais. Concluiu-se que os cirurgiães-dentistas devem conscientizar-se dos riscos ocupacionais e que trabalhos educativos no sentido de preven‡Æo das doen‡as profissionais sÆo necess rios.


The present study aimed to collect evidence related to occupational diseases to which dental surgeons are exposed. A literature review on the subject was elaborated through the application of explicit and systematic search methods, critical appraisal, and synthesis of selected information. The studies were chosen from electronic databases (Pubmed, Bireme, Nature, SciELO and Cochrane), consulted in the period from 1990 to 2013 on the following topics: “occupational diseases in Dentistry”, “occupational hazards in Dentistry”, “dental work”, “occupational disease Dentistry”, “occupational hazards”, “dentist”, “dental surgeon”, in Portuguese and English. Twenty-one articles were selected from a total of 40 potentially relevant studies identified in the databases concerning various occupational diseases. It was concluded that dentists should become aware of occupational hazards and that further educational programs towards the prevention of occupational diseases are still necessary.


Subject(s)
Occupational Dentistry , Occupational Diseases , Occupational Health , Occupational Risks
6.
J. appl. oral sci ; 16(1): 24-29, Jan.-Feb. 2008. ilus, tab
Article in English | LILACS | ID: lil-472685

ABSTRACT

This study compared, by scanning electron microscopy (SEM), the efficacy of three solvents on the removal of filling materials from dentinal tubules during endodontic retreatment. Forty human maxillary canines with straight canals were prepared according to a crown-down technique and enlarged to a#30 apical file size, before obturation with gutta-percha and a zinc-oxide-eugenol based sealer. The samples were stored for 3 months before being randomly assigned to four groups: chloroform (n=10), orange oil (n=10), eucalyptol (n=10) and control (n=10). Solvents were applied to a reservoir created on the coronal root third using Gates Glidden drills. The total time for retreatment using the solvents was 5 minutes per tooth. Following retreatment the roots were split longitudinally for SEM evaluation. SEM images were digitized, analyzed using Image ProPlus 4.5 software, and the number of dentinal tubules free of filling material from the middle and apical thirds was recorded. No significant difference was found among the solvent groups regarding the number of dentinal tubules free of root filling remnants in the middle and apical root thirds (p>0.05). However, the control group had fewer dentinal tubules free of filling material (p<0.05). Under the tested conditions, it may be concluded that there was no significant difference among the solvents used to obtain dentinal tubules free of filling material remnants.


Subject(s)
Humans , Dental Pulp Cavity/drug effects , Root Canal Irrigants/therapeutic use , Root Canal Preparation/methods , Solvents/therapeutic use , Chloroform/therapeutic use , Cuspid/ultrastructure , Cyclohexanols/therapeutic use , Dental Pulp Cavity/ultrastructure , Dentin/drug effects , Dentin/ultrastructure , Eucalyptus , Gutta-Percha/therapeutic use , Image Processing, Computer-Assisted , Materials Testing , Microscopy, Electron, Scanning , Monoterpenes/therapeutic use , Plant Oils/therapeutic use , Retreatment , Root Canal Obturation , Root Canal Filling Materials/therapeutic use , Time Factors , Tooth Apex/drug effects , Tooth Apex/ultrastructure , Zinc Oxide-Eugenol Cement/therapeutic use
7.
RPG rev. pos-grad ; 12(4): 430-436, out.-dez. 2005. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-556098

ABSTRACT

O presente estudo objetivou determinar os teores de cloro e oxigênio em ppm, quando empregado hipoclorito de sódio (NaOCl) nas concentrações de 0,5%; 1,0% e 5,0% associado com peróxido de hidrogênio (H2O2) 3%, ácido cítrico 10% e EDTA 17%. Avaliaram-se, também, as reações do creme Endo PTC com NaOCl 0,5% e 5%. A determinação do teor de cloro (Cl2) foi realizada no espectrofotômetro ultravioleta visível analógico pelo método alaranjado de metila. O teor de oxigênio (O2) foi analisado volumetricamente pelo método de Winkler. O tempo reacional para produzir cloro e oxigênio foi 3 minutos. Padronizou-se o volume em 10 ml para as soluções testadas. Para realizar a reação do creme Endo PTC, utilizou-se 0,2 g com 2 ml das soluções de NaOCl 0,5% e 5,0%, no mesmo período de tempo. Os resultados demonstraram que a produção de CL2 foi encontrada nas reações entre NaOCl com ácido cítrico (0,07; 0,11 e 0,15 ppm) e com EDTA (0,01; 0,05 e 0,08 ppm). A produção de O2 foi encontrada nas reações do NaOCl com H2O2 (0,03; 0,18 e 0,49 ppm). Na reação com Endo PTC e NaOCl a 0,5% e 5,0%, observou-se também a produção de O2 (0,08 e 0,43 ppm), porém o gás cloro Cl2 só foi constatado na reação com NaOCl 5,0% (0,06 ppm). Concluiu-se que formação de Cl2 foi maior quando NaOCl 5% reagiu com ácido cítrico. A maior formação de O2 foi encontrada na reação de NaOCl 5% com H2O2, assim como na reação do NaOCl 5% com Endo PTC.


Subject(s)
Chemical Reactions , Endodontics , Root Canal Irrigants , Hydrogen Peroxide , Oxygen , Sodium Hypochlorite
8.
Rev. bras. odontol ; 60(5): 310-313, set.-out. 2003. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-404158

ABSTRACT

O presente trabalho verificou a necessidade do uso e da troca de próteses (parcial e total) de 103 pacientes com idade acima de 60 anos envolvidos no Programa Interdisciplinar de Geriatria e Gerontologia da UFF. No que diz respeito à necessidade de utilização de próteses tanto parciais como totais, verificou-se que, em relação aos homens, as mulheres tinham a menor probabilidade de permanecer sem os dentes (p<0,05). Entretanto, com relação à necessidade de troca das próteses, não foi observada diferença estatística entre os sexos. As alterações vasculares da cavidade bucal foram significativas nos pacientes com faixa etária maior


Subject(s)
Humans , Male , Female , Aged , Denture, Complete , Denture, Partial , DMF Index , Geriatric Dentistry
9.
Rev. bras. odontol ; 59(6): 378-379, nov.-dez. 2002. tab
Article in Portuguese | LILACS, BBO | ID: lil-331299

ABSTRACT

Baseou-se verificar in vitro a capacidade de quelaçäo de íons de cálcio (Ca++) da dentina dos canais radiculares, quando do emprego de EDTA a 17 por cento e ácido cítrico a 10 por cento. A determinaçäo do teor de cálcio nas amostras foi feita pela espectrofotometria de absorçäo atômica. Os valores das leituras foram analisados estatisticamente tendo como nível crítico de significância 5 por cento. Considerando os intervalos de tempo de 3, 10 e 15 minutos versus substâncias, näo existiu diferença significativa entre o ácido cítrico a 10 por cento e EDTA a 17 por cento (p>0,05)


Subject(s)
Citric Acid/administration & dosage , Edetic Acid/administration & dosage , Chelation Therapy , Dentin , In Vitro Techniques , Cuspid
10.
Rev. bras. odontol ; 59(1): 11-13, jan.-fev. 2002.
Article in Portuguese | LILACS, BBO | ID: lil-312582

ABSTRACT

Este trabalho objetiva verificar a capacidade de vedaçäo do Primer & Bond 2.1© e Histoacryl, utilizados no revestimento das paredes de dentina empregando analisador de imagens como meio de avaliaçäo. Impermeabilizaram-se externamente as raízes com SuperBonder e distribuiram aleatoriamente em três grupos: GI- grupo controle - sem tratamento; GII- as paredes receberam Primer & Bond© 2.1 e GIII- Histoacryl©. Aplicou-se Rodamina B a 1 por cento no interior do canal, aguardando-se 48 horas a 37ºC. A análise de penetraçäo do corante foi realizada pelo Imaging Densitometer Software Molecular Analyst, sendo estatisticamente significante (5 por cento) nos grupos controle (GI) e no Primer & Bond©2.1 (GII), näo existindo diferença entre eles. No do Histoacryl© (GIII), a penetraçäo do corante näo foi observada


Subject(s)
Dentin-Bonding Agents , Root Canal Obturation/methods , Radiography, Dental, Digital , Rhodamines , Root Canal Filling Materials
11.
Rev. bras. odontol ; 53(1): 21-3, jan.-fev. 1996. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-168358

ABSTRACT

Foram usados os terceiros premolares inferiores de cinco cäes sem raça definida. Pulpectomia foi realizada em todos os dentes. Os dentes do lado esquerdo tiveram seus canais imediatamente obturados, embora precariamente, e os do lado direito deixados abertos ao meio bucal por 60 dias. Os premolares esquerdos foram apicetomizados e retrobturados após um mês da primeira sessäo. Os do lado direito, depois de dois meses da primeira sessäo: após limpeza de suas câmaras, elas foram seladas com amálgama de prata após o que, imediatamente, procedeu-se a apicetomia e a obturaçäo retrógrada com o Ketac Bond. Decorridos 180 dias da última sessäo, os animais foram sacrificados e verificados os resultados histopatológicos. A formaçäo óssea foi observada apenas no lado esquerdo e sempre na ausência de processo inflamatório severo, com exceçäo de um único caso


Subject(s)
Animals , Dogs , Bicuspid , Glass Ionomer Cements/therapeutic use , Pulpectomy , Retrograde Obturation , Dental Amalgam
12.
Rev. bras. odontol ; 50(3): 42-5, maio-jun. 1993. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-857454

ABSTRACT

Foram usados os 3ºs pré-molares inferiores de 5 cães sem raça definida. Pulpectomia foi realizada em todos os dentes e os do lado esquerdo tiveram seus canais imediatamente obturados, embora precariamente, e os do lado direito deixados abertos ao meio bucal por 60 dias. Os pré-molares esquerdos foram apicetomizados e retrobturados após 1 mês da primeira sessão. Os do lado direito, depois de 2 meses da 1ª sessão, após limpeza de suas câmaras, estas foram seladas com amálgama de prata após o que, imediatamente, procedeu-se a apicetomia e obturação retrógrada com o mesmo material. Decorridos 180 dias da última sessão, os animais foram sacrificados e verificados os resultados histopatológicos. No que toca a inflamação, a condição mais severa (grau 3) apareceu em ambos os lados, embora sob o ponto de vista estatístico, não houvesse diferença significativa entre estes, no lado direito a ocorrência de inflamação tendeu a ser mais intensa


Subject(s)
Animals , Dogs , Glass Ionomer Cements , Retrograde Obturation
13.
Rev. bras. odontol ; 43(3): 25-32, maio-jun. 1986. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-872113

ABSTRACT

Esta pesquisa objetivou verificar o efeito do ácido cítrico (solução a 10 por cento) na remoção da dentina "esmagada" (smear layer) comumente existente na superfície do canal radicular após a biomecânica. O ácido cítrico mostrou-se eficaz quando utilizado como irrigante final seguido de irrigação com água destilada, deixando os túbulos dentinários desobstruídos


Subject(s)
Humans , Citrates , Dentin/ultrastructure , Root Canal Irrigants , In Vitro Techniques
SELECTION OF CITATIONS
SEARCH DETAIL